Planning Permission Ireland
GrantedEnergyDecided 19 March 2026

Lands at Cavan Business & Technology Park Dublin Road, Killygarry Cavan, Co. Cavan.

Development of a new 38kV/MV electrical substation at Cavan Business & Technology Park.

2660024 · Cavan County Council · Lodged 23 January 2026

Reference
2660024
Authority
Cavan County Council
Register status
Decided
Type
PERMISSION
Received
23 January 2026

Summary

AI-generated

The application seeks permission for a new 38kV/MV Gas Insulated Switchgear (GIS) electrical substation on a 1.929-hectare site. The development includes a fenced compound, prefabricated modules, transformers, and a 12-metre telecommunication pole.

Energysubstationinfrastructureelectricity
Floor area
99 m²

Generated from the description above by an AI model and may contain mistakes. The council’s description is the authoritative record.

Official record

Development description

  • For permission for development of a 38kv/mv gas insulated switchgear (gis) electrical substation at this site (c. 1.929 ha) located at cavan business & technology park, dublin road, killygarry, cavan, co. Cavan. The site is generally bound to the north by a private site access road; to the east by the cavan business & technology park private access road; to the south by unoccupied greenfield land; and to the west by an existing industrial property. The proposed development will consist of the provision of a new 38 kv / mv gas insulated switchgear (gis) electrical substation and will include the following elements
  • Removal of existing mv timber poleset and associated overhead line
  • Construction of: i. A new substation compound (c. 1,999 sq. M) with a 2.6 m high palisade fence ii. 1 no. Prefabricated 38 kv gis module and foundation (c. 31 m2 and c. 5.139 m high); iii. 1 no. Prefabricated mv gis module and foundation (c. 34 m2 and c. 4.64 m high); iv. 1 no. Prefabricated control room module and foundation (c. 34 m2 and c. 4.64 m high); v. 2 no. 38/20 kv 18.75 mva transformers and associated bunds (c. 4.67 m high ea. ); vi. Telecommunication scada pole of c. 12 m in height; vii. Associated and ancillary outdoor electrical equipment and other apparatus, including installation of underground cables; viii. All associated site development works including provision of access roads, lighting, boundary fences, landscaping, site services including drainage and all ancillary site development works

Land-use zoning

What this land is zoned for

General Enterprise and EmploymentSI
Provide for and improve general enterprise and employment generating uses.

National zoning type: Industrial, enterprise, employment

Objective set by the Cavan County Development Plan incorporating a Local Area Plan for Cavan Town 2022-2028 (2022–2028). The planning authority decides each application on its own merits — this is the zoning context, not a compliance assessment.

Read the zoning objectives in the development plan

Key dates

Timeline

  1. Application received23 January 2026
  2. Decision due19 March 2026
  3. Decision issued19 March 2026
  4. Grant issued27 April 2026
  5. Permission expiry26 April 2031

In the area

Applications near this site

Other planning applications within about 500 m — what else is being proposed or built nearby.

Related developments

Similar applications

Ranked by what these developments actually propose, not by matching words — so you can see how comparable applications were decided.

Community

Discussion

What local people think about this application.

Nobody watching yet

Community sentiment

No votes yet

Nobody has voted on this application yet.

Community sentiment — a straw poll of people who visited this page, not a statutory submission. To make a valid observation you must submit it to the planning authority.

Sign in to have your say on this application.

No comments yet. Be the first to say what you think about this application.

Sign in to join the discussion on this application.