Kilshane Road, Kilshane, Finglas, Dublin 11

Revisions to a previously approved gas turbine power generation station in Finglas.

FW25A/0523E · Fingal County Council · Lodged 28 November 2025

Reference
FW25A/0523E
Authority
Fingal County Council
Register status
Decided
Type
Permission
Received
28 November 2025

Summary

AI-generated

The application seeks amendments to an approved power station. This includes increasing the height and floor area of the administrative and warehouse building, altering its facade, and making minor adjustments to the gas turbine and evaporative cooler.

Energyenergypower stationindustrial
Floor area
428 m²

Generated from the description above by an AI model and may contain mistakes. The council’s description is the authoritative record.

Official record

Development description

  • Kilshane energy ltd. Intends to apply for planning permission for revisions to previously approved gas turbine power generation station (reg. Ref: fw22a/0204) at a site located at kilshane road, kilshane, finglas, dublin 11, comprising the following amendments
  • Revisions to previously approved administrative/warehouse building consisting of the following: (a) revised internal layout consisting of addition of new stair core and lift at ground floor level connecting to new storage area at first floor level (428 m2 gfa), increasing the total gfa of the administrative/warehouse building from 855 m2 to 1283 m2. (b) revised façade design to elevations including revised fenestration to south elevation, revised fenestration and door design to west elevation, revised fenestration to east elevation and provision of new external fire staircase and first floor level access door to east elevation. (c) increase in height of administrative/warehouse building by 1 m to 7.38 m. (d) revised colour of material finish from green to dark grey
  • Revisions to previously approved gas turbine including revised shape of evaporative cooler, addition of servicing gantries and the slight moving of the gas turbine c. 5.57 m to the north as demonstrated on the enclosed architectural plans (drg no. Drawing no. 25043-pl-04.1) internal gas turbine machinery and installation as part of revised gas turbine model to be provided to later specialist design as previously approved under reg. Ref. Fw22a/0204.3. Revised size and location of fin fan coolers within power island compound as demonstrated on enclosed architectural plans
  • Revisions to layout of diesel storage compound to now provide 1 no. Larger fuel storage tank with an increase in maximum height from 16.2 m to 20 m and an increase in diameter from 24.4 m to 49 m
  • Revised design and location of the packaged electronic/electrical control compartment (peecc) within the power island compound to now comprise a single storey stilted building raised 2.6 m above ground level, accessed via 2 no. External stairs and a new servicing gantry at finished floor level, with a floor-to-ceiling height of 3.25 m and an overall height of 6 m, and an increase in gfa from 72 m² to 148.51 m² together with façade changes
  • Revised design and location of bop power distribution centre within power island compound as demonstrated on enclosed architectural drawings including increase in gfa from 129 m2 to 160.6 m2 together with façade changes including revised fenestration to west and east elevations
  • The addition of new aux equipment block (connected to the gas turbine) with a gfa of 361.20 m2 and height ranging from 7.65m to 9.59m and new servicing gantries for the purposes of sheltering specialist equipment and machinery as identified on the enclosed architectural drawings
  • The addition of a hvac structure within power island compound with a maximum height of 8.84 m which supports two hvac units on the top and the starter transformer and excitation transformer below
  • Revision to previously approved acoustic wall within power island compound consisting of a slight decrease in length from 107.0m to 101.6m
  • Removal of previously approved 16.2m high x 18.3m dia demin water tank and replaced with separate demin water tank to be added as a non-permanent structure rather a small cube refill tank
  • Removal and replacement of select number of smaller equipment items as identified on the equipment identification drawings prepared by cwpa planning & architecture (drawing no. 25043-pl-14)
  • Minor revision to internal road network as demonstrated on enclosed architectural drawings to accommodate proposed amendments. Additional information received 13/02/2026 significant additional information received 25/02/2026 clarification of additional information received 30/03/2026

Land-use zoning

What this land is zoned for

HI - Heavy IndustrySI
Provide for heavy industry

National zoning type: General industry

Objective set by the The Fingal Development Plan 2023 – 2029 (2023–2029). The planning authority decides each application on its own merits — this is the zoning context, not a compliance assessment.

Read the zoning objectives in the development plan

Key dates

Timeline

  1. Application received28 November 2025
  2. Decision due24 April 2026
  3. Decision issued23 April 2026

In the area

Applications near this site

Other planning applications within about 500 m — what else is being proposed or built nearby.

Related developments

Similar applications

Ranked by what these developments actually propose, not by matching words — so you can see how comparable applications were decided.

Community

Discussion

What local people think about this application.

Nobody watching yet

Community sentiment

No votes yet

Nobody has voted on this application yet.

Community sentiment — a straw poll of people who visited this page, not a statutory submission. To make a valid observation you must submit it to the planning authority.

Sign in to have your say on this application.

No comments yet. Be the first to say what you think about this application.

Sign in to join the discussion on this application.

Comments are moderated and are the opinions of the people who wrote them. They form no part of the statutory planning process — to make a valid observation you must submit it to the planning authority.