GrantedIndustrialDecided 16 February 2021

Avoca River Park, Shelton Abbey & Kilbride, Arklow

Demolition of industrial buildings to construct three data centre buildings and standby power compounds in Arklow.

201285 · Wicklow County Council · Lodged 15 December 2020

Reference
201285
Authority
Wicklow County Council
Register status
Decided
Type
PERMISSION
Received
15 December 2020
Residential units
1
Floor area
1 m²

Summary

AI-generated

This major development involves the demolition of existing industrial buildings totalling 2,784.4 sqm. In their place, three data centre buildings with mezzanine offices, standby diesel generator compounds, and fuel storage tanks will be constructed.

Industrialdata centredemolitioninfrastructure

Generated from the description above by an AI model and may contain mistakes. The council’s description is the authoritative record.

Official record

Development description

  • Demolition of existing ind building units totalling (c. 2784.4m2) comprising of a c. 7.1m high overall main building (c. 2460m2), a c. 4.2m high sub-station (c. 107.3m2), a c. 3.6m high guardhouse (c. 106.2m2), a c. 3.6m high east-building (c. 39.1m2), c. 5m high water tank (c. 56.8m2) &c. 2.6m high pump house building (c. 15.1m2), assoc works
  • Dev of 3 no. Data centre buildings, ancillary offices & plant comprising of: data centre building a, - a single storey data centre building, with mezzanine 1st floor level offices (gfa c. 10,564m2, building height c. 13,658m & structures c. 15,137m), made up of 2 no. Data halls & loading areas with assoc 2 no. Dock levellers & including 10 no. C. 14m high flues, & adjacent 1 no. Standby power generation compounds, consisting of 10 no. Hv diesel generators &belly tanks (gfa c. 530 m2), 1 no. Storage fuel tank (gfa c. 15m2). Data centre building b – a single storey data centre building with mezzanine 1st floor level offices (gfa c. 18,508m2, building height c. 13,658m &structures c. 15,137m), made up of 4 no. Data halls &loading areas with associated 2 no. Dock levellers &including 20 no. C. 14m high flues, &adjacent 2 no. Standby power generation compounds, consisting of 20 no. Hv diesel generators &belly tanks (gfa c. 1,060 m2), 2 no. Storage fuel tanks (gfa c. 30m2). Data centre building c – a single storey data centre building with mezzanine 1st floor level offices (gfa c. 18,508m2, building height c. 13,658m & structures c. 15,137m), made up of 4 no. Data halls & loading areas with associated 2 no. Dock levellers &including 20 no. C. 14m high flues, &adjacent 2 no. Standby power generation compounds, consisting of 20 no. Hv diesel generators & belly tanks (gfa c. 1,060 m2), 2 no. Storage fuel tanks (gfa c. 30m2)
  • Upgrading of existing 110 kv substation to comprise of compound (c. 8539m2) consisting of 11 kv gis switch room (gfa c. 708m2), &4 no. External transformers (gfa c. 550m2), a grid connection, security fence & all assoc works & services
  • Dev of 1 no. Fire hydrant pump hse (gfa c. 129m2) with sprinkler tank (c. 49m2), 1 no. Single storey security guard hse (gfa c. 48m2) &2 no. Vehicular accesses, internal access rds & 224 no. Surface car parking spaces
  • An upgraded attenuation basin, a proposed ww treatment plant &polishing filter
  • All assoc site services, with c. 2.7m high palisade fence, landscaping, boundary & all assoc site development works above & below ground. An eiar has been prepared in respect of the proposed dev

Key dates

Timeline

  1. Application received15 December 2020
  2. Decision due17 February 2021
  3. Decision issued16 February 2021
  4. Grant issued22 March 2021
  5. Permission expiry21 March 2026

In the area

Applications near this site

Other planning applications within about 500 m — what else is being proposed or built nearby.

Related developments

Similar applications

Ranked by what these developments actually propose, not by matching words — so you can see how comparable applications were decided.

Community

Discussion

What local people think about this application.

Nobody watching yet

Community sentiment

No votes yet

Nobody has voted on this application yet.

Community sentiment — a straw poll of people who visited this page, not a statutory submission. To make a valid observation you must submit it to the planning authority.

Sign in to have your say on this application.

No comments yet. Be the first to say what you think about this application.

Sign in to join the discussion on this application.

Comments are moderated and are the opinions of the people who wrote them. They form no part of the statutory planning process — to make a valid observation you must submit it to the planning authority.