Designing for BER A1 in Ireland — Fabric First, Heat Pump, and What the BER Assessor Measures

Last updated 30/6/2026 · Reviewed 30/6/2026
On this page

BER A1 needs wall U-value 0.13–0.18, roof 0.13–0.16, floor 0.13, airtightness 1–3 m³/m²·hr, and a heat pump.

Designing for BER A1 in Ireland means getting the fabric right and pairing it with a heat pump. The numbers: wall U-value 0.13–0.18 W/m²K (Part L 2022 backstop is 0.18; A1 typically needs 0.13–0.16), roof 0.13–0.16 (backstop 0.16; A1 typically 0.13), floor 0.13, airtightness 1–3 m³/m²·hr at 50 Pa (Passive House is ≤0.6), and a heat pump (6–9 kW air-to-water, depending on the floor area and fabric). The BER assessor measures: floor area, U-values, airtightness (blower door test), and the heating system. Inputs go into the DEAP (Dwelling Energy Assessment Procedure) calculation. Fabric first: invest in insulation and airtightness before spending on heating. A well-insulated house lets you size the heat pump 6 kW smaller, saving €1,500–€3,500 on the heat pump itself and €300–€500/year on running cost.

When this matters most

You're at design stage and need to target BER A1.

When this doesn't apply

You're aiming for a lower BER (A2, A3) for cost reasons.

Sources

SEAI, BER and DEAP guidance. https://www.seai.ie/

Building Regulations 2023, TGD Part L (Conservation of fuel and energy — Dwellings). https://www.gov.ie/

Frequently asked questions

What U-value do I need for BER A1 in Ireland?

Wall 0.13–0.18 W/m²K, roof 0.13–0.16, floor 0.13, windows 0.8–1.2. Airtightness 1–3 m³/m²·hr at 50 Pa. Plus a heat pump (6–9 kW air-to-water).

How much does it cost to design for BER A1?

Adds €5,000–€15,000 to the wall insulation cost over a Part L 2022 backstop build. Saves €3,000–€5,000 on the heat pump size. Lifetime saving: €5,000–€15,000 on energy and capital cost over 20 years.

What is the DEAP calculation?

Dwelling Energy Assessment Procedure. The Irish method for calculating BER. Inputs: floor area, U-values, airtightness, heating system. Output: energy use and CO2 emissions, mapped to a BER rating A1–G.

When this matters most

You're at design stage and need to target BER A1.

When this doesn't apply

You're aiming for a lower BER (A2, A3) for cost reasons.

Where to go next

Free pre-planning reportCheck a site before you apply
Map of applicationsEvery application on one map, with zoning and heritage layers
AreasCounties and towns
Planning statisticsThe national picture, and every council side by side
CommencementsWhat actually got built
Property salesWhat it sold for
Ask the planning assistantPlain-English questions