Block €110–€160/m² wall. ICF €180–€240/m². Timber frame €200–€280/m². Pick the U-value, the speed, the lifetime cost.

[@portabletext/react] Unknown block type "span", specify a component for it in the `components.types` prop

When this matters most

[@portabletext/react] Unknown block type "span", specify a component for it in the `components.types` prop

When this doesn't apply

[@portabletext/react] Unknown block type "span", specify a component for it in the `components.types` prop

Sources

Building Regulations 2023, TGD Part L (Conservation of fuel and energy — Dwellings), Department of Housing. https://www.gov.ie/

NSAI, I.S. EN ISO 13790 — Energy performance of buildings. https://www.nsai.ie/

Your options at a glance

Blockwork

Concrete blocks laid by a block-layer, then insulated externally. The Irish default. Cheapest per m² of wall, slowest to weathertight, and easiest to find trades for.

Cost
€110–€160/m² wall
U-value (A1 target)
0.13–0.16 W/m²K
Build time
6–10 weeks for shell
Thermal mass
High
Trades
Block-layers available everywhere in Ireland

Best for A tight budget on a standard site, with access for block deliveries and a local block-trained crew.

Avoid if You're targeting airtightness <1 m³/m²·hr, or site access is restricted (narrow lane, no crane time, etc.).

ICF (Insulated Concrete Formwork)

Hollow polystyrene blocks stacked like Lego, filled with concrete. The polystyrene stays as insulation. Mid-cost, fast to weathertight, proven airtight.

Cost
€180–€240/m² wall
U-value (A1 target)
0.13–0.18 W/m²K
Build time
3–5 weeks for shell
Thermal mass
High (concrete core)
Trades
Specialist ICF crew required

Best for Sites with restricted access where panels beat pallets, and airtightness targets below 1 m³/m²·hr.

Avoid if You can't get an experienced ICF crew in your county. Poor ICF installation is worse than good blockwork.

Timber frame

Factory-cut panels delivered to site and craned into place. Fastest to weathertight, easiest to hit A1 BER, very airtight by default.

Cost
€200–€280/m² wall
U-value (A1 target)
0.13–0.16 W/m²K
Build time
1–3 weeks for shell (panels)
Thermal mass
Low
Trades
Specialist TF crew + crane

Best for BER A1 targets, airtightness <1, remote sites without crane access for blocks, or any project where shell speed matters.

Avoid if You specifically want thermal mass (blockwork or ICF deliver it) or your architect has no timber-frame detailing experience.

SIPs (Structural Insulated Panels)

Factory-laminated panels: two OSB faces with rigid foam core. Premium speed and airtightness — at premium price.

Cost
€240–€320/m² wall
U-value (A1 target)
0.10–0.15 W/m²K
Build time
1–2 weeks for shell
Thermal mass
Very low
Trades
Specialist SIPs crew + crane

Best for A premium build where shell speed, very high airtightness, and best-in-class U-values all matter and budget is secondary.

Avoid if Budget is tight, or you need lots of on-site adjustments. SIPs work best when the design is locked at factory order.

Blockwork: blocks laid, then insulated externally.
Irish cavity wall cross-section showing two concrete block leaves with a cavity filled with insulation between them. The cavity is the widest layer in the wall. Finished with render on the outside and plaster skim on the inside.

Blockwork: blocks laid, then insulated externally.

ICF: hollow polystyrene forms, filled with concrete.
ICF cross-section: two leaves of expanded polystyrene around a central concrete core, plasterboard on the inside, render on the outside.

ICF: hollow polystyrene forms, filled with concrete.

Timber frame: factory-cut timber panels, sheathed and insulated.
Irish masonry-clad timber frame wall in isometric cutaway view showing from outside to inside: render, 100mm outer block, 50mm ventilated cavity, breathable membrane, OSB sheathing, solid 150mm timber studs at regular intervals with insulation between them (visible at stud edges), airtightness membrane (factory-applied), 50mm PIR insulation, vertical battens at 600mm centres creating a service cavity for electrics and plumbing, and plasterboard finish on the inside.

Timber frame: factory-cut timber panels, sheathed and insulated.

Quick decision matrix

If your situation isThen choose
Site has poor access (narrow lane, low-loader limited)ICF or timber frame (delivered as panels, not pallets of block)
BER A1 is a must-haveTimber frame or ICF (default with proper insulation)
Tight budget, standard siteBlockwork with external insulation (cheapest warm wall)
Airtightness target is <1 m³/m²·hrICF or SIPs (proven airtight at panel level)
Build on a remote site with no craneTimber frame (panelised) or SIPs
Want thermal massBlockwork or ICF (concrete has mass; timber and SIPs do not)
Local trades are timber-frame-trainedTimber frame (cheaper labour)
Local trades are block-trainedBlockwork

Frequently asked questions

What's the cheapest wall system?

Blockwork with external insulation. €110–€160/m² of wall. Trades are everywhere, materials are stocked locally.

What's the warmest wall?

SIPs. U-value as low as 0.10 with standard 200 mm panel. Timber frame and ICF both reach 0.13–0.18 with normal build-up.

Which wall system is fastest to build?

SIPs and timber frame, both at 2–4 weeks for walling on a 150 m² house. ICF is 3–5 weeks. Blockwork is 6–9 weeks.

Can I get BER A1 with any wall system?

Yes, if insulation and airtightness details are right. Timber frame and ICF make it easiest; SIPs and CLT make it cheapest in design effort.

Do mortgage lenders care which system?

Generally no, but some have preferred suppliers or a panel of approved frames. Confirm with your lender before detailed design.